Relay > Time Relays

Time relay GreenChip TMR

Time relay GreenChip TMR

  • Specifications:
  • Real-time clock
  • No. of on-off: max 8 per day
  • Output: 1 relay (max 10A (250V))
  • Power: ~ 220 (25, -40), 50 (± 1) Hz
  • Power consumption: less than 3W
  • housing mounting on DIN-rail
  • Size: 61mm x 35mm x 15mm
Count Price
From1шт340грн
From3шт333грн
Code: 13
шт.
Є в наявності

Переглянути відгуки (0)

time switch - a device in which the relay element responsive to a control signal with some delay. Delay relay is controlled by the impact on the rate of change of the physical quantity affecting the relay element. Accuracy of putting delay relay mainly on a scale analog potentiometer.

When applied multi-band timers, first you define a range, and then within a certain range of time delay exhibited smoothly potentiometer. Scale potentiometer switch is graded as a percentage, from 5% to 100% of the final value of the time range.

Should be considered in the relay no possibility of putting the minimum time delay relay less than 5 % of full scale range, for example, for the range of 1: 00 to put the time delay can not be less than 3 minutes.

Despite the fact that the time switch equipped with a stable reference oscillator, when the ambient temperature of the temperature dependence exists delay. In the application of the device over a wide temperature range of this dependence should be taken into account.

Voltage relay time must be set by the manufacturer within. Otherwise, the accuracy of the relay is not guaranteed. Note that at low power, the relay operation time when heated. When intimate setting in a closet or under high ambient temperature must be monitored resulting thermal regime.

In order to increase resource relay must always load the relay current as small as possible. If necessary, very large security operation mounted on the relay output time intermediate power relay. Relay vemeni included applying power, or by gating contact - carefully examine the connection type. At the end of the time delay relay time need some time to recover, as a rule, this time is in the range 50... 75ms. During this time span the relay does not respond to any input control signals that should be considered in " frequent " the relay is time.

Timer, as well as any relay can be separated into different categories depending on the physical nature of the input and output signal. Most commonly used in the art electrical timers managed to communicate electrical signals.

Fields of application timers - timers.

Coordination with timers heating and heating

  1. control of electric heaters - oil radiators, heaters, convectors, fan heaters, electric under floor heating, infrared panels.
  2. functioning control gas boilers.
  3. control of the electric water heating equipment - boilers.

For

time control of lighting

  1. On and off the street and house lighting.
  2. Enabling and disabling lighting indoors.
  3. Enabling and disabling light advertising and display lighting, billboards, signage.

for aquariums and terrariums.

  1. on and off lighting in aquariums and terrariums. Enabling and disabling
  2. compressors in the aquarium for water oxygen at a certain time.
  3. Enabling and disabling electric heaters, humidifiers and many other devices climate control in aquariums and terrariums.
  4. Feeding fish, reptiles and other denizens of time.

For

infield and agriculture.

  1. Irrigation - including a pump for watering plants in opredennyh period.
  2. for greenhouses - turning on and off lighting, heating, saturation humidity allows you to create an optimal microclimate for plant growth.

for telepresence.

Inclusion - off lighting and other electrical randomly enables organizations visibility presence in the room of people that discourages " uninvited " guests when you're not home.


Reviews of the Time relay GreenChip TMR: