Smart BMS 12 s 100A
- Specifications:
- Brand: RJXZS
- Number of battery cells: 12
- Maximum discharge current: 100A
- Maximum charging current: 100A
- Maximum peak discharge current: 200A ≤ ±5A
- Charge voltage: 4.2V * 12 = 50.4V
- Cell balancing current: 50mA
- Voltage balance: 3.3 ~ 4.2V
- Maximum charging voltage: 4.25V ≤ ±0.05V
- Minimum voltage at discharge: 2.8V ≤ ±0.05V
- Operating temperature range: 20˚C -75˚C
- Size: 138*103*15mm
- Size: 136mm x 103mm x 15mm
Переглянути відгуки (0)
Smart BMS 12 s 100A
- Functions of the
- electronic on/off battery (reliable load connection/disconnection, flexible load management)
- independent voltage monitoring on each battery element
- protection against overheating of the BMS board and battery cells
- control of charge and discharge currents
- protection from other dangerous situations (overcharge and overdischarge is high and low voltage on any battery cell, overcooling and overheating, short circuit, overloads).
Smart BMS 12s 100A are used in household appliances, portable mobile electronics, renewable energy sources. Often they occur in systems with solar batteries, as well as in wind generators. Using Smart BMS, the user can receive battery status data. If the indicators reach critical values, the microprocessor automatically turns off the battery. This allows you to protect the battery from premature failure, which greatly extends its lifetime.
Specifications Smart BMS 12S 100A:
| № | Name | Value | |
|---|---|---|---|
| 1 | Voltage | Charge Voltage: | DC: 50,4V CC/CV | Single cell balancing voltage: | 4.2V | 2 | Current | Single cell balancing current: | 50 mA | Maximum continuous charging current: | 100A | Maximum continuous discharging current: | 100A | 3 | Over-charge protection | Over-charge detection voltage: | 4.25V ≤ ±0.05V | Over-charge testing delay time: | 1,2 s | Over-charge release voltage: | 4.2V ≤ ±0.05V | 4 | Over-discharge protection | Over-discharge detection voltage: | 2.8V ≤ ±0.05V | Over-discharge delay time: | 144 ms | Over-discharge release voltage: | 2.9V ≤ ±0.05V | 5 | Over-current protection | Over-current testing voltage: | 0.15V | Over-current detection current: | 200A ≤ ±5A | Over-current delay time: | 9ms | Release conditions: | Cut load, automatic recovery | 6 | Short circuit protection | Detection condition: | external short circuit | Detection delay time: | 320 ms | Release conditions: | Cut load, automatic recovery | 7 | Resistance | Protection circuitry (MOSFET): | 0.2 Ohm | 8 | Temperature | Over Temperature: | 75°C | Over Temperature release: | 55°C | Operating temperature range: | -20˚C ~ +75˚C | Storage temperature range: | -20˚C ~ +125°C | 9 | Size: | 138*103*15 mm |